Current condition
|
Possible causes of defect
|
Recommendations to elimination
|
The control lamp of pressure of oil is not lighted
|
The lamp in a combination of devices has burnt down
|
Replace a lamp
|
Has burnt down a safety lock IG/METER
|
Replace a safety lock, to check up on short circuit
|
Malfunction of the printed-circuit board in a combination of devices
|
Replace the printed-circuit board
|
Malfunction of the gauge of pressure of oil
|
Replace the gauge of pressure of oil
|
Malfunction of conducting or grounding
|
Repair
|