Suzuka Grandee Vitara
The general information
Maintenance service and greasing
Heater, ventilation and the conditioner
Steering
Suspension bracket
Wheels and tyres
Forward приводной a shaft shaft/bearing. An oil epiploon
Kardannye shaft
Brake system
Engines
Fuel system
Ignition system
Start system
Release system
Transmissions
Coupling
Transfer
- Forward and back differentials
   - Forward диффренциал
       The general description
       Diagnostics
      - Service out of a workshop
          Servicing
         - Check
            Control system of a full drive
            Drive
            The air pump
          Removal and installation
         Removal
         Installation
    Back differential
Windows, mirrors, locks and security measures. An immobilizer
Electric equipment






Check

Control system of a full drive

 PERFORMANCE ORDER

    Establish the special tool on a hose for air, having connected it between the air pump and differential (actuator). Tighten against the stop an adjusting bolt of the special tool. Close a lateral aperture for check of air by means of a fuel hose as a deaf stopper.
      The special tool:
        (A): 09918-18110 (B): 09367-04002

Be cautious not to bend a hose.

    Include the switch of ignition and switch the lever of a gear change from position 2Н in position 4Н. Check up that the motor has earned (its sound) within 1 second is audible and has stopped, when the arrow of the device of the special tool has shown the specified value of pressure. Check up, whether there is no air leak. Pressure specifications: 30.0 – 45.0 килоПаскалей (0.30 – 0.45 kg/sm2, 4.25 – 6.40 pounds on sq. inch). Check up, that the value of pressure shown on a dial of the special tool, has fallen, as soon as the gear change lever is switched in position 2Н. Start the motor, again having switched the gear change lever in position 4Н. Ослабьте an adjusting bolt to lower value of pressure on a device dial. The motor should earn and stop again in approximately 4 seconds. Having weakened an adjusting bolt of the special tool, switch the gear change lever in position N or 2Н, and then in position 4L or 4Н. The pump motor should stop approximately in 10 seconds after the motor has started to work.
1 — the corked hose
2 — an adjusting bolt
3 — a tube (to the air pump)
4 — a hose (to the holder of differential)
5 — the differential case